Remote Commands of the 1xEV-DO BTS Analyzer Option (K84) R&S FSL
1300.2519.12 6.646 E-11
Characteristics
RST value: -
SCPI: device-specific
Mode
EVDO
CONFigure:CDPower[:BTS]:CTABle:DATA
This command defines a channel table.
Parameter
For one table line, eight values are specified .
<channel type>, <code class>, <code number>, <radio configuration>, <reserved1>,
<reserved2>, <status>, <CDP relative>, ....
Channel Type The channel type is numerically coded as follows:
0 = PILOT
1 = MAC
2 = PREAMBLE with 64 chip length
3 = PREAMBLE with 128 chip length
4 = PREAMBLE with 256 chip length
5 = PREAMBLE with 512 chip length
6 = PREAMBLE with 1024 chip length
7 = DATA
Code Class Depending on channel type, fixed: PILOT: 5, MAC: 6,
PREAMBLE: 5 and DATA: 4 (spreading factor =
2^code class)
Code number 0...spreading factor–1
Modulation Modulation type including mapping:
0 = BPSK–I
1 = BPSK–Q
2 = QPSK
3 = 8–PSK
4 = 16–QAM
Modulation types QPSK/8–PSK/16–QAM have
complex values.
Reserved 1 Always 0 (reserved)
Reserved 2 Always 0 (reserved)
Status
0: inactive, 1:active
Can be used in a setting command to disable a channel
temporarily
CDP relative Any with setting command, relative with CDP query
Before using this command, you must set the name of the channel table using the
CONFigure:CDPower[:BTS]:CTABle:NAME command.