1xEV-DO BTS Analyzer (Option K84) R&S FSL
1300.2519.12 4.390 E-11
Adjust Ref Level
Adjusts the reference level to the measured channel power. This ensures that the settings of the
RF attenuation and reference level are optimally adjusted to the signal level without overloading
the R&S FSL or limiting the dynamic range by a too small S/N ratio.
Current measurements are aborted when pressing the softkey and resumed after the automatic
level detection is finished.
For further details refer also to the Adjust Ref Level softkey in the measurement menu of the
base unit.
Remote: CDP:LEV:ADJ
Softkeys of the frequency menu (1xEV-DO BTS Analyzer mode)
The following table shows all softkeys available in the frequency menu in 1xEV-DO BTS Analyzer
mode. It is possible that your instrument configuration does not provide all softkeys. If a softkey is only
available with a special option, model or (measurement) mode, this information is delivered in the
corresponding softkey description.
Command
Center
Start
Stop
CF-Stepsize
Center
For details refer to the Center softkey in the frequency menu of the base unit.
Start
Opens an edit dialog box to define the start frequency. For further details refer to the Start
softkey in the frequency menu of the base unit.
Note that the softkey is unavailable for Code Domain and CCDF measurements.
Remote: FREQ:STAR 800 MHz
Stop
Opens an edit dialog box to define the stop frequency. For further details refer to the Stop
softkey in the frequency menu of the base unit.
Note that the softkey is unavailable for Code Domain and CCDF measurements.
Remote: FREQ:STOP 1.500 MHz
CF-Stepsize
For details including the submenu refer to the CF Stepsize softkey in the frequency menu of the
base unit.