R&S FSL CALCulate Subsystem
1300.2519.12 6.113 E-11
C
haracteristics
*RST value: OFF
SCPI: device–specific
M
ode
A, CDMA, EVDO
CALCulate:STATistics:NSAMples
This command sets the number of measurement points to be acquired for the statistical
measurement functions.
Parameter
100 to 1E9
Example
CALC:STAT:NSAM 500
Sets the num ber of measurem ent points to be acquired to 500 .
Characteristics
*RST value: 100000
SCPI: device–specific
Mode
A, CATV, CDMA, EVDO
CALCulate:STATistics:PRESet
This command resets the scaling of the X and Y axes in a statistical measurement. The
following values are set:
x–axis ref level: –20 dBm
x–axis range APD: 100 dB
x–axis range CCDF: 20 dB
y–axis upper limit: 1.0
y–axis lower limit: 1E–6
This command is an event and therefore has no *RST value and no query.
Example
CALC:STAT:PRES
Resets the scaling for statistical functions
Characteristics
*RST value: –
SCPI: device–specific
Mode
A, CATV, CDMA, EVDO