R&S FSL CALCulate Subsystem
1300.2519.12 6.119 E-11
CALCulate:UNIT Subsystem
The CALCulate:UNIT subsystem defines the units for the parameters that can be set and the
measurement results.
Commands of the CALCulate:UNIT Subsystem
CALCulate<1|2>:UNIT:POWer
CALCulate<1|2>:UNIT:POWer
This command selects the unit for power.
The numeric suffixes <1|2> are not relevant.
Parameter
DBM | V | A | W | DBPW | WATT | DBPT | DBUV | DBMV | VOLT | DBUA | AMPere
Example
CALC:UNIT:POW DBM
Sets the power unit to dBm.
Characteristics
*RST value: dBm
SCPI: device–specific