MMEMory Subsystem R&S FSL
1300.2519.12 6.168 E-11
MMEMory:STORe<1|2>:STATe:NEXT
This command stores the current device settings in a *.FSL.dfl file. The file name used in the
last saving process is automatically counted up to the next unused name. The numeric suffix in
STORe<1|2> is irrelevant with this command.
This command is an event and therefore has no *RST value and no query.
Example
MMEM:STOR:STAT 1,'Save'
Saves the current device settings in the file Save.FSL.dfl.
MMEM:STOR:STAT:NEXT
Saves the current device settings in the file Save_001.FSL.dfl
MMEM:STOR:STAT:NEXT
Saves the current device settings in the file Save_002.FSL.dfl
Characteristics
RST value: -
SCPI: device-specific
Mode
all
MMEMory:STORe<1|2>:TRACe
This command stores the selected trace in a file with ASCII format. The file format is described
in chapter 4 "Instrument Functions - Analyzer", section "Setting Traces - TRACE Key", ASCII
File Export softkey.
The decimal separator (decimal point or comma) for floating-point numerals contained in the file
is defined with the FORMat:DEXPort:DSEParator command.
This command is an event and therefore has no *RST value and no query.
Parameter
1 to 6,<file_name>
with 1 to 6 = selected measurement curve trace 1 to 6 and <file_name> = DOS file name
The file name includes indication of the path and the drive name. Indication of the path complies
with DOS conventions.
Example
MMEM:STOR:TRAC 3,'TEST.ASC'
Stores trace 3 in the file TEST.ASC.
Characteristics
*RST value: -
SCPI: device-specific