EasyManua.ls Logo

Rohde & Schwarz R&S FSL3 - Page 951

Rohde & Schwarz R&S FSL3
1734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SENSe Subsystem R&S FSL
1300.2519.12 6.192 E-11
[
SENSe<1|2>:]ESPectrum:RANGe<1...20>:DELete
This command deletes the specified range. The range numbers are updated accordingly. The
reference range cannot be deleted. A minimum of three ranges is mandatory.
The numeric suffixes <1...20> specify the range. The numeric suffixes <1|2> are not relevant.
This command is an event and therefore has no *RST value and no query.
This command is available from firmware version 1.80.
Example
ESP:RANG4:DEL
Deletes range 4.
Characteristics
RST value:
SCPI: device–specific
Mode
A, CDMA, EVDO
[SENSe<1|2>:]ESPectrum:RANGe<1...20>[:FREQuency]:STARt
This command sets the start frequency for the specified range.
In order to change the start/stop frequency of the first/last range, select the appropriate span. If
you set a span that is smaller than the overall span of the ranges, the measurement includes
only the ranges that lie within the defined span and have a minimum span of 20 Hz. The first
and last range are adapted to the given span as long as the minimum span of 20 Hz is not
violated.
The numeric suffixes <1...20> specify the range. The numeric suffixes <1|2> are not relevant.
This command is available from firmware version 1.80.
Parameter
see rules in chapter 4, "Ranges and settings"
Example
ESP:RANG1:STAR 100000000
Sets the start frequency for range 1 to 100 MHz.
Characteristics
RST value: –250.0 MHz (range 1), –2.52 MHz (range 2), 2.52 MHz (range 3)
SCPI: device–specific
Mode
A, CDMA, EVDO

Table of Contents

Related product manuals