R&S FSL SENSe Subsystem
1300.2519.12 6.233 E-11
C
haracteristics
*RST value: EDGE
SCPI: device–specific
M
ode
A
[SENSe<1|2>:]SWEep:MODE
This command changes from Spectrum Analyzer to Spectrum Emission Mask or Spurious
Emissions measurement mode and back.
The numeric suffixes <1|2> are not relevant.
This command is available from firmware version 1.80.
Parameter
AUTO Switches to Spectrum Analyzer measurement mode or stays in the
current mode if it is not ESP / LIST
ESPectrum Spectrum Emission Mask measurement mode
LIST Spurious Emissions measurement mode
Example
SWE:MODE ESP
Sets the Spectrum Emission Mask measurement mode.
Characteristics
RST value: AUTO
SCPI: device–specific
Mode
A, CDMA, EVDO
[SENSe<1|2>:]SWEep:POINts
This command defines the number of measurement points to be collected during one sweep.
The numeric suffixes <1|2> are not relevant.
Parameter
101 to 32001
Example
SWE:POIN 251
Characteristics
*RST value: 501
SCPI: conform
Mode
A, CATV, CDMA, EVDO, SPECM