SimradEK15
Example2StartRangeinasurfacerelatedechogram
Inasurfaceechogram,settheStartRangevalueto10meters.Thiswillmake
theechogramstartfrom10metersbelowtheseasurface(providedthatthe
transduceroffsethasbeendened).SetRangetothecurrentdepthplus20
meters.Theechogramwillnowshowtheareafrom10metersbelowthesea
surface,anddownto10meters“below”thebottom.Thebottomcontouris
easilydetectedwhenthedepthchanges.
5SetRangetoAuto.
SetStartRangeto0.
Observethechangesmadetothesurfacerelatedechogram.
6Clickinabottomrelatedechogramtomakeit“active”.
7ObservetheRangeandStartRangebuttonsontheMainmenu.
Example3StartRangeandRangeinbottomrelatedechogram
Inabottomechogram,settheStartRangevalueto–5meters.Thiswillmake
theechogramstartfrom5metersabovethebottom.SetRangetothe5meters
plus10=15meters.Theechogramwillnowshowtheareafrom5meters
abovethedepth,anddownto10meters“below”thebottom.Thebottom
contourwillappearasaatline.
8SetRangeto15.
SetStartRangeto5.
Observethechangesmadetothebottomrelatedechogram.
Savingthecurrentusersettings
Purpose
Thisprocedureexplainshowtosavethecurrentcongurationandparametersettings.
Ifyouhaveseveraluserswithfavouritecongurations,ifyouworkwithdifferentgears,
orwithdifferenthardwarecongurations,depthorbottomconditions,werecommend
thatyousavetheEK15operationalparametersforfutureuse.
Relatedtopics
•UserSettingsdialogboxonpage142
Procedure
1ObservetheMainmenu.ItisnormallylocatedontherighthandsideoftheEK15
presentation.
2OntheMainmenu,clickUserSettingstoopentheUserSettingsdialogbox.
TheUserSettingsdialogboxallowsyoutosavethecurrentusersettings(parameter
selections),andtoretrievefactoryorpreviouslysavedusersettings.
3IntheFactorySettingslist,clicktherequestedfactorysetting.
32
351718/C