Operationalprocedures
5ClickOKtosavethecurrentsettingsandclosethedialogbox.
Removinginterferenceusingsequentialpinging
Purpose
Thisprocedureexplainshowyoucaninitiatesequentialpingingtoremoveinterference.
Thisfunctionisusefulifyouhavemultipletransceiversusingthesamefrequency.
Description
TheSequentialpingingfunctioncanbeusedifyouhavemorethanone
transceiver/transducerinuseontheEK15system.Whenactivated,eachindividual
transceiverwill‘ping’insequence,onebyone.Whennotactivated,alltransceivers
will‘ping’simultaneously.
Relatedtopics
•NormalOperationdialogboxonpage154
Procedure
1ClicktheOperationicon.
ThisiconislocatedundertheMainmenu.Itisusedtoopenthe
Operationmenu.
2ClickNormalOperationtoopentheNormalOperationdialogbox.
ThepurposeoftheNormalOperationdialogboxistoofferyouanoverviewofthe
currenttransceiverparameters,andtoprovideyouwiththeabilitytochangethem.
3ClicktoenableSequentialPinging.
4ClickOKtosavethecurrentsettingsandclosethedialogbox.
MakingiteasiertoseethebottomusingWhiteLineand
BottomLine
Purpose
TheEchogramdialogboxallowsyoutoenableaBottomlineoraWhitelinetoeasier
identifythebottom.Thisprocedureexplainshowtoenablethesefeatures.
Description
ThemarkerlinesenabledhereareexplainedinsectionEchogramsinchapterDisplay
view.
Relatedtopics
•Echogrammarkersonpage120
•Activemenuonpage139
•Echogram;Linestabonpage208
351718/C
69