EM500 Open-Loop Vector Control Inverter User Manual
265
6: Modbus Communication
Abnormality Status
7: Factory Test Status
Communication card only read the parameters. Refer to corresponding manuals of
communication expansion cards.
No.
Function
Range
Unit
Default
Type
F10.48
Communication Card
Software Version
×
A read only parameter of communication card.
No.
Function
Range
Unit
Default
Type
F10.49
number of process data
received
116
2
F10.50
number of process data
transmission
116
2
F10.51
Process data address
setting mode selection
0keypad
1Master
0
F10.52
Communication card
manual reset selection
0disable
1enable
0
Communication card function, as shown in the communication card manual.
EM500 inverter support CANSinee communication protocol based on CAN, which
realize the communication between PC or PLC with inverter or more communication
between the inverters.
No.
Function
Range
Unit
Default
Type
F10.53
CANSinee
Communication
address
1~31
1
When the Inverter as a slave into the bus, must have its own unique address. The
setting range is 1 ~ 31, that is, the whole network supports up to 31 slaves.
0 is the broadcast address, all the inverters can be identified from the machine,
this address does not need to set.
No.
Function
Range
Unit
Default
Type
F10.54
CANSinee
Communication
0
125K
1250K
0