EasyManua.ls Logo

Sinee EM500 - Page 419

Sinee EM500
459 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM500 Open-Loop Vector Control Inverter User Manual
419
Return: 01 03 0C 00 11 00 00 00 00 01 2C 00 00 00 0053 5B (Normal)
Return: 01 83 04 40 F3 (When abnormal, assuming that slave fails)
Send
Normal return
Abnormal return
*
Frame Header
≥3.5 idle characters
1
Address
01
Address
01
01
2
Function Code
03
Function Code
03
83
3
Initial Address
Hi
13
Number of Bytes
0C
04(assumption)
4
Initial Address
Lo
00
Register Value Hi
(F19.00)
00
40
5
Number of
Registers Hi
00
Register Value Lo
(F19.00)
11
F3
6
Number of
Registers Lo
06
Register Value Hi
(F19.01)
00
7
CRC Parity Lo
C1
Register Value Lo
(F19.01)
00
8
CRC Parity Hi
4C
Register Value Hi
(F19.02)
00
9
Register Value Lo
(F19.02)
00
10
Register Value Hi
(F19.03)
01
11
Register Value Lo
(F19.03)
2C
12
Register Value Hi
(F19.04)
00
13
Register Value Lo
(F19.04)
00
14
Register Value Hi
(F19.05)
00
15
Register Value Lo
(F19.05)
00
16
CRC Parity Lo
53
17
CRC Parity Hi
5B
*
Frame End
≥3.5 idle characters
2) Check whether the lines work
Send: 01 08 00 00 AA 55 5E 94