4-29
Group 03: External Digital Input and Output Parameters
Code Parameter Name Setting Range Default Unit
Control mode
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2 Attribute
Mode (Stop
Command)
54: Reserved
55: Reserved
56: Reserved
57: Reserved
58: Safety Function
59: Reserved
60: Reserved
61: Reserved
62: EPS Function
- - - - - - -
- - - - - - -
- - - - - - -
O O O O O O O
- - - - - - -
- - - - - - -
- - - - - - -
O O O O O O O
03-08
(S1~S8) DI Scan
Time
0: Scan Time 4ms
1: Scan Time 8ms
1 - O O O O O O O
03-09
Multi-Function
Terminal S1-S4
Type Selection
xxx0b: S1 A Contact
xxx1b: S1 B Contact
0000b - O O O O O O O
xx0xb: S2 A Contact
xx1xb: S2 B Contact
x0xxb: S3 A Contact
x1xxb: S3 B Contact
0xxxb: S4 A Contact
1xxxb: S4 B Contact
03-10
Multi-Function
Terminal S5-S8
Type Selection
xxx0b: S5 A Contact
xxx1b: S5 B Contact
0000b - O O O O O O O
xx0xb: S6 A Contact
xx1xb: S6 B Contact
x0xxb: S7 A Contact
x1xxb: S7 B Contact
0xxxb: S8 A Contact
1xxxb: S8 B Contact
03-11
Relay (R1A-R1C)
Output
0: During Running
0 -
O O O O O O O
1: Fault Contact Output
O O O O O O O
2: Frequency Agree
O O O O O O O
3: Setting Frequency
Agree
O O O O O O O
4: Frequency Detection 1
(> 03-13+03-14)
O O O O O O O
5: Frequency Detection 2
(< 03-13+03-14)
O O O O O O O
6: Automatic Restart
O O O O O O O
7: Reserved
- - - - - - -
8: Reserved
- - - - - - -
9: Baseblock
O O O O O O O
10: Reserved
- - - - - - -
11: Reserved
- - - - - - -
12: Over-Torque
Detection
O O O O O O O
13: Current Agree
O O O O O O O