4-76
Group 22: PM Motor Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F+P
G
SLV SV
PMS
V
PM
SLV
SLV2
22-00
PM Motor Rated
Power
0.00~600.00 KVA kW X X X X O O X
22-01
Reserved
22-02
PM Motor Rated
Current
25%~200% inverter’s
rated current
KVA A X X X X O O X
22-03
PM Motor ‘s Pole
Number
2~96 6 poles X X X X O O X
22-04
PM Motor’s
Rotation Speed
1~30000 1500 rpm X X X X O O X
22-05
PM Motor’s
Maximum Rotation
Speed
1~60000 1500 rpm X X X X O O X
22-06
PM Motor Rated
Frequency
0.1~599.0 75.0 Hz X X X X O O X
22-07 Reserved
22-08
PM Encoder Type
0: TAMAGAWA Non
Wire-Saving Encoder
0 X X X X O X X
1: TAMAGAWA
Wire-Saving Encoder
2: SUMTAK Wire-Saving
Encoder
3: General Incremental
Encoder
4:Sine Wave
22-09 Reserved
22-10
PM SLV Start
Current
0 ~ 120%
Motor Rated Current
50 % X X X X X O X
22-11
I/F Mode Start
Frequency
Switching Point
1.0 ~ 20 5 % X X X X X O X
22-12
KP Value of Speed
Estimation
1~10000
2000 - X X X X X O X
22-13
KI Value of Speed
Estimation
1~1024
40 - X X X X X O X
22-14
Armature
Resistance of PM
Motor
0.001 ~ 30.000 1.000 XX XX O O X
22-15
D-axis Inductance
of PM Motor
0.01 ~ 300.00 10.00 mH X X X X O O X
22-16
Q-axis Inductance
of PM Motor
0.01 ~ 300.00 10.00 mH X X X X O O X
22-17 Reserved
22-18
Flux-Weakening
Limit
0~100 0 % X X X X O O X