3-42
Basic Specifications 400V class
Inverter capacity (HP) 1 2 3 5 7.5 10 15 20 25 30
Out
ut rated
Heavy Duty type
H.D.
(150%/1min)
Rated output Capacity (KVA)
2.6 3.2 4.2 7 11.3 13.7 18.3 23.6 29.7 34.3
Rated output current (A)
3.4 4.2 5.5 9.2 14.8 18 24 31 39 45
Maximum applicable motor
*1
HP
(KW)
1
(0.75)
2
(1.5)
3
(2.2)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
Motor rated current (A)
*1
1.7 3.1 4.2 7 10.1 12.6 18.6 24.8 31.1 36.3
Normal Duty type
N.D.
(120%/1min)
Rated output Capacity (KVA)
3.1 4.1 5.3 9.2 13.3 17.5 23.6 29.0 33.5 44.2
Rated output current (A)
4.1 5.4 6.9 12.1 17.5 23 31 38 44 58
Maximum applicable motor
*1
HP
(KW)
2
(1.5)
3
(2.2)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
Motor rated current (A)
*1
3.1 4.2 7 10.1 12.6 18.6 24.8 31.1 36.3 48.7
The maximum output voltage (V)
3-phase 380V~ 480V
The maximum output frequency (Hz)
Based on parameter setting 0.1~599.0 Hz
Powe
Rated voltage, frequency
3-phase 380V ~ 480V, 50/60Hz
Allowable voltage fluctuation
-15% ~ +10%
Allowable frequency fluctuation
±5%
Inverter capacity (HP) 40 50 60 75 100 125 150 175 215
Out
ut rated
Heavy Duty type
H.D.
(150%/1min)
Rated output Capacity (KVA)
45.7 57.2 69.3 89.9 114 137 165 198 225
Rated output current (A)
60 75 91 118 150 180 216 260 295
Maximum applicable motor
*1
HP
(KW)
40
(30)
50
(37)
60
(45)
75
(55)
100
(75)
125
(90)
150
(110)
175
(132)
215
(160)
Motor rated current (A)
*1
48.7 59 70.5 88 114 145 175 205 248
Normal Duty type
N.D.
(120%/1min)
Rated output Capacity (KVA)
55.6 67.1 78.5 111 128 159 191 226 250
Rated output current (A)
73 88 103 145 168 208 250 296 328
Maximum applicable motor
*1
HP
(KW)
50
(37)
60
(45)
75
(55)
100
(75)
125
(90)
150
(110)
175
(132)
215
(160)
250
(185)
Motor rated current (A)
*1
59 70.5 88 114 145 175 205 248 270
The maximum output voltage (V)
3-phase 380V~480V
The maximum output frequency (Hz)
Based on parameter setting 0.1~599.0 Hz
Powe
Rated voltage, frequency
3-phase 380V ~ 480V, 50/60Hz
Allowable voltage fluctuation
-15% ~ +10%
Allowable frequency fluctuation
±5%