4-22
Group 00: Basic Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
00-47 User parameter 6 00-47 - O O O O O O O *7
00-48 User parameter 7 00-48 - O O O O O O O *7
00-49 User parameter 8
Set 13-06 = 1, start user
parameter. The setting
range is 01-00 ~24-06.
(only for LCD keypad)
00-49 - O O O O O O O *7
00-50 User parameter 9 00-50 - O O O O O O O *7
00-51 User parameter 10 00-51 - O O O O O O O *7
00-52 User parameter 11 00-52 - O O O O O O O *7
00-53 User parameter 12 00-53 - O O O O O O O *7
00-54 User parameter13 00-54 - O O O O O O O *7
00-55 User parameter 14 00-55 - O O O O O O O *7
00-56 User parameter 15 00-56 - O O O O O O O *7
00-57
SV High Speed
Mode
0: SV High Speed
Mode1
0 - X X X O X X X
1: SV High Speed
Mode2
*: Refer to the following attachment 1.
**: Before to set up 00-32 Application, it should do initialized setting (parameter 13-08) first. When setting
00-32, the I/O port function changed automatically. To avoid accident, be sure to confirm the I/O port
signal of inverter and external terminal control.
*** If parameter 00-27 is set to ND mode, group 02 motor 1 parameter will automatically adjust to more
than 1 class of it.
If parameter 00-27 is set to HD mode, group 02 motor 1 parameter will automatically adjust to the same
class of it.
It is suggested that parameter 00-27 be set first before motor performs auto-tuning because the
parameter will make the motor parameter automatically be changed.
***** If the maximum output frequency of motor is over 300HZ,the frequency resolution is changed to
0.1Hz
Group 01: V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
01-00
V/F Curve
Selection
0~FF F - O O X X X X O *3
01-01 Reserved
01-02
Maximum Output
Frequency of
Motor 1
5.0~599.0 60.0 Hz O O O O O O O
01-03
Maximum Output
Voltage of Motor
1
200V: 0.1~255.0 220.0
V O O X X X X O
400V: 0.2~510.0 440.0
575V: 0.1~670.0
575.0
690V: 0.1~804.0
690.0

Table of Contents