3-43
Inverter capacity (HP) 270 300 375
425
Output rated
Heavy Duty type
H.D.
(150%/1min)
Rated Output capacity (KVA)
290 343 400
446
Rated output current (A)
380 450 523
585
Maximum applicable motor
*1
HP
(KW)
270
(200)
300
(220)
375
(280)
425
(315)
Motor rated current (A)
*1
300 348 465 500
Normal Duty type
N.D.
(120%/1min)
Rated Output capacity (KVA)
332 393 446
446
Rated output current (A)
435 515 585
585
Maximum applicable motor
*1
HP
(KW)
300
(220)
335
(250)
425
(315)
425
(315)
Motor rated current (A)
*1
348 465 500 615
The maximum output voltage (V)
3-phase 380V~480V
The maximum output frequency (Hz)
Based on parameter setting 0.1~ 599.0 Hz
Power
Rated voltage, frequency
3-phase 380V ~ 480V 50/60Hz
Allowable voltage fluctuation
-15% ~ +10%
Allowable frequency fluctuation
±5%
Basic Specifications 575/690V class
Inverter capacity (HP) 1 2 3 5 7.5 10 15 20 25 30
Output rated
Rated output Capacity (KVA)
1.7 3.0 4.2 6.6 9.9 11.4 17.9 22.7 26.3 32.3
Heavy Duty type
H.D.
(150%/1min)
Rated output current (A)
1.7 3.0 4.2 6.6 9.9 11.4 15 19 22 27
Maximum applicable motor
*1
HP
(KW) for 575v
1
(0.75)
2
(1.5)
3
(2.2)
5
(3.7)
7.5
(5.5)
10
(7.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
Maximum applicable motor
*1
HP
(KW) for 690v
1
(0.75)
2
(1.5)
3
(2.2)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
Rated output Capacity (KVA)
3.0 4.2 5.8 8.8 12.2 14.5 22.7 26.3 32.3 40.6
Normal Duty
type
N.D.
(120%/1min)
Rated output current (A)
3.0 4.2
5.8
8.8
12.2
14.5
19 22 27 34
Maximum applicable motor
*1
HP
(KW) for 575v
2
(1.5)
3
(2.2)
4
(3)
5
(3.7)
10
(7.5)
10
(7.5)
15 (11)
20
(15)
25
(18.5)
30
(22)
Maximum applicable motor
*1
HP
(KW) for 690v
- - - - - - 20 (15)
25
(18.5)
30
(22)
40
(30)
The maximum output voltage (V)
3-phase575/690V
The maximum output frequency (Hz)
Based on parameter setting 0.1~599.0 Hz
Power
Rated voltage, frequency
3-phase 575V, 50/60Hz 3-phase 575/690v, 50/60Hz
Allowable voltage fluctuation
-15% ~ +10%
Allowable frequency fluctuation
±5%

Table of Contents