3-6 
3.5   Removing the Front Cover and Keypad 
 
  Caution 
  Before making any wiring connections to the inverter the front cover needs to be 
removed. 
 
  It is not required to remove the digital operator before making any wiring connections. 
 
  Models 200V, 1 – 25 HP and 400V, 1 – 30 HP and 
575V/690V 1 – 40 HP have a 
plastic cover. Loosen the screws and remove the cover to gain access to the terminals 
and make wiring connections. Place the plastic cover back and fasten screws when 
wiring connections have been made. 
 
  Models 200V, 30 - 150HP and 400V, 40 - 425HP and 
690V 50 - 270HP have a metal 
cover. Loosen the screws and remove the cover to gain access to the terminals and 
make wiring connections. Place the metal cover back and fasten screws when wiring 
connections have been made. 
 
3.5.1 Standard Type 
 
(a) 200V: 1 ~ 7.5 HP / 400V: 1 ~ 7.5 HP /575V: 1~3HP 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 1: Unscrew
  Step 2: Remove cover