Loading...
11-5
11.2 AC Line Reactors
An AC line reactor can be used for any of the following:
- Capacity of power system is much larger than the inverter rating.
- Inverter mounted close to the power system (in 33ft / 10 meters).
- Reduce harmonic contribution (improve power factor) back to the power line.
- Protect inverter input diode front-end by reducing short-circuit current.
- Minimize overvoltage trips due to voltage transients.
Please select the AC line reactor based on the inverter rating according to the following table.
Table 11.2.1 List of AC Line Reactors
Model AC reactor
Input
Voltage
HP
Rated Current(A)
HD/ND
Part Number
Specification
(mH / A)
Rated Current(A)
200V
1Ø/3Ø
1 5/6
JNACL1P7M15A2 1.7mH 15A
2 8/9.6
JNACL1P1M20A2 1.1mH
20A
3 11/12
JNACL0P85M25A2 0.85mH
25A
200V
5.4 17.5/22
JNACL0P46M25A2
0.46mH
25A
7.5 25/30
JNACL0P34M40A2
0.34mH
40A
10 33/42
JNACL0P24M50A2
0.24mH
50A
15 47/56
JNACL0P18M70A2
0.18mH
70A
20 60/69
JNACL0P15M85A2
0.15mH
85A
25 73/79
JNACL0P13M95A2 0.13mH 95A
30 85/110
JNACL0P09M140A2 0.09mH 140A
40 115/138
JNACL0P07M170A2 0.07mH 170A
50 145/169
JNACL0P06M210A2 0.06mH 210A
60 180/200
JNACL0P05M250A2 0.05mH 250A
75 215/250
JNACL0P04M310A2 0.04mH 310A
100 283/312
JNACL0P03M390A2 0.03mH 390A
125 346/400
JNACL0P03M490A2 0.03mH 490A
150 415/450
JNACL0P02M550A2 0.02mH 550A

Table of Contents