4-105
00-32=7: Crane* Consult TECO for the detailed settings
Parameter Name Value
00-00 Control mode selection 0: V/F
00-05 Main Frequency Command Source Selection 0: keypad
00-14 Acceleration time 1 3.0 sec
00-15 Deceleration time 1 3.0 sec
00-27 HD/ND Mode selection 0: HD
11-01 Carrier frequency 5.0kHz
05-01 Frequency setting of speed-stage 0 6.0 Hz
05-02 Frequency setting of speed-stage 1 30.0 Hz
05-03 Frequency setting of speed-stage 2 60.0 Hz
03-04 Multi-function terminal Function setting-S5
2: Multi-speed/position setting
command 1
03-05 Multi-function terminal Function setting-S6
3: Multi-speed/position setting
command 2
03-28 Photo-coupler output 23: Source of operation command
08-00 Stall prevention function
xx1x : Stall prevention ineffective in
deceleration
08-09 Selection of input phase loss protection 1: Enable
08-10 Selection of output phase loss protection 1: Enable
00- 33 Modified Parameters
Range
0: Disable
1:
Enable
This parameter automatically lists all the adjusted parameters. When the default value is adjusted and 00-33=1, it
will list all the parameters different from default values in the advanced modes and these parameters can be
edited directly. The adjusted parameters list displays only when 00-33 is set from 0 to 1 or 00-33=1 at start up.
If user wants to restore to the original editing interface, it is only required to set parameter 00-33=0.
This function can display 250 adjusted parameters. If they are more than 250 parameters, it will list the adjusted
parameters before 250.
Note: It is only for LCD keypad.