6-1 
Chapter 6 Speed Reference Command Configuration 
The inverter offers users several choices to set the speed reference source. The most commonly used 
methods are described in the next sections. 
 
Frequency reference command is selected with parameter 00-05. 
 
00-05: Main Frequency Command (Frequency Source) 
 
This function sets the frequency command source. 
 
Setting Range: 0 to 5 
 
To set parameter 00-05: 
- After power-up press the DSP/FUN key 
- Set Group 00 (Basic Fun), and select parameter -05 with the UP/DOWN ▲ and ▼ keys and press 
the READ/ ENTER key.   
 
 
 
00-05  Main Frequency Command Source Selection 
Range 
0: Keypad 
1: External control (analog) 
2: Terminal command UP / DOWN 
3: Communication control (RS-485) 
4: Pulse input 
5: Reserved 
6: Reserved 
7: AI2 Auxiliary Frequency   
 
 
6.1 Reference from Keypad 
 
  LED Keypad: 
 
Use the </RESET, ▲ and ▼ keys to change the speed reference and then press the READ/ ENTER 
key. Refer to section 4.1.5 for more details.   
   
  LCD Keypad: 
 
Press the READ/ ENTER key first and use the </RESET, ▲ and ▼ keys to change the speed 
reference.