8-7
8.6 Forward and Reverse Jog
The jog forward command is used in combination with multi-function digital input function #6 (Jog
Forward) and the jog reverse command is used in combination with multi-function digital input function
#7 (Jog Reverse).
Example: Jog Forward input terminal S5 (03-04 = 06) and Jog Reverse input terminal S7 (03-06=7) with
NPN wiring.
8.7 Direct / Unattended Startup
The unattended startup function prevents the inverter from starting automatically when a run command
is present at time of power-up. To use USP command set one of the multi-function digital input
functions to #50 (USP Startup).
Unattended Startup Protection