11-18 
11.6 Other Options 
A. Analog Operator 
 
‧
Besides the standard LED & LCD keypad in inverter A510S, analog dial operator (JNEP-16-A) is also 
available. Refer to the following figure. This operator can be pulled out and movable. Refer to the   
following figure for wiring with inverter.     
 
 
R
S
T
R
S
T
Circuit-breaker
Foward
Stop
24VG
10V   for speed setting
(+10V, 20 mA)
GND 0V
AI1   Main speed command
0 ~ 10V
2k 
Main frequency setting
A01
GND
FM
Analo g output
B1/P B2
V
W
IM
U
R1A
R1B
R1
C
Multi-fu nction t erminal 
output
250V AC,  below 1A 
30V  DC,   below 1A 
DO1
DO
G
DO2
Mult-function output 
1, 2
(OPEN 
COLLECTOR
48V, 50mA)
Run
Consistent 
frequency
A510S
Analog operat or 
(JNEP-16-A)
S1
S6
(a) Appearance  (b) Wiring 
 
B. Blank cover and keypad extension cable 
 
When used for remote control purposes, the keypad can be removed and remotely connected with an 
extension cable. Extension cables are available in the following lengths: 1m (3.3ft), 2m (6.6ft), 3m (10ft), 
and 5m (16.4ft).   
 
 
 
 
 
 
 
Remote control  
Name  Model  Specification
LED digital 
operator wire 
with blank 
cover 
JN5-CB-01M 
1m (3.3ft) 
JN5-CB-02M 
2m (6.6ft) 
JN5-CB-03M 
3m (10ft) 
JN5-CB-05M 
5m (16.4ft)