4-291
20-19 Overspeed (OS) selection
Range
0: Deceleration to stop
1: Coast to stop
2: Continue to operate
20-20 Overspeed (OS) detection level
Range
0~120 %
20-21
Overspeed (OS) detection time
Range
0.0~2.0 sec
20-22
Speed deviation (DEV) selection
Range
0: Deceleration to stop
1: Coast to stop
2: Continue to operate
20-23
Speed deviation (DEV) detection level
Range
0~50 %
20-24
Speed deviation (DEV) detection time
Range
0.0~10.0 sec
20-25
Selection of PG Open
Range
0: Deceleration to stop
1: Coast to stop
2: Continue to operate
20-26
Detection time of PG Open
Range
0.0~10.0 Sec
20-27 PG pulse number
Range
0~60000 ppr
20-28 Selection of PG rotation direction
Range
0: Forward as counter -clockwise rotation
1: Forward as clockwise rotation
20-29
PG pulse dividing ratio
Range
001~132
20-30
PG gear ratio 1
Range
1~1000
20-31
PG gear ratio 2
Range
1~1000
PG card is required (JN5-PG-O/JN5-PG-L/JN5-PG-PM)
PG pulse divider ratio can be set parameter 20-29.