4-179
Figure 4.4.47 Adjustment of lower limit of frequency reference
04-05=9: Jump frequency 4
Multi-function analog input AI2 can be used to adjust Jump frequency 4.
Maximum output frequency (01-02, Fmax) = 100%. Setting 11-08 to 11-10 to 0.0Hz turns of the Jump frequency
function.
Figure 4.4.48 Jump frequency 4 Setting Operation
04-05=10: Added to AI1
Multi-function analog input AI2 can be used as a bias level for analog input AI1.