4-124
02 - IM Motor Parameters
02- 00 No-load current of motor 1
Range
0.01~600.00 A
02- 01 Rated current of motor 1
Range
V/F and V/F+PG modes are 10%~200% of inverter’s rated current. SLV, SV modes are
25%~200% of inverter’s rated current.
02-03
Rated rotation speed of motor1
Range
0~60000 rpm
02- 04 Rated voltage of motor1
Range
200V: 50.0~240.0 V
400V: 100.0~480.0 V
575V: 150.0~670.0 V
690V: 200.0~804.0 V
02- 05 Rated power of motor 1
Range
0.01~600.00 KW
02-06
Rated frequency of motor 1
Range
5.0~599.0 Hz+
02-07
Pole of motor 1
Range
2~16
02-09
Excitation current of motor 1 <1>
Range
15.0~70.0 %
02-10
Core saturation coefficient 1 of motor 1 <1>
Range
1~100 %
02-11
Core saturation coefficient 2 of motor 1 <1>
Range
1~100 %
02-12
Core saturation coefficient 3 of motor 1 <1>
Range
80~300 %
02-13
Core loss of motor 1
Range
0.0~15.0 %
02-15
Resistance between wires of motor 1
Range
0.001~60.000 Ω