4-154
03-1X=28: Traverse operation UP status
Output is controlled by frequency wobbling operation; refer to Parameter group 19 for details.
03-1X=29: During Traverse operation status
Output is controlled by the acceleration period or frequency wobbling operation, refer to Parameter group 19 for
details.
03-1X=30: Motor 2 selected
Output is active when motor 2 is selected.
03-1X=31: Zero Servo Status (Position mode)
Output is active when Zero-servo operation is enabled and the load is locked into position.
03-1X=32: Communication control contacts
Communication location: 2507H,control by RY3 RY2 RY1.RY3 and RY2 will execute if DO1,DO2 and DO3 all set
communication control, and 2507H set 5(101)
03-1X=37: PID Feedback Loss Detection Output
When PID feedback loss occurs (refer to the setting of parameters 10-11~10-13), it performs the state of ON.
03-1X=38: Brake Release
The state of ON means release brake is active. Refer to parameters 03-41~03-42 for the details.
03-1X=39: Frequency Detection 1 (dedicated for Crane)
03-1X=40: Frequency Output
Refer to table 4.4.9 for the operation of frequency detection.
03-1X=41: Position Agree (Position Mode)
Position search is completed at position mode, then ON.
03-1X=45: PID Sleep
It will inform when PID sleep ON.
03-1X=50: Frequency Detection
3
Please refer to
Table 4.4.9 Frequency detection operation
03-1X=51: Frequency Detection
4
Please refer to
Table 4.4.9 Frequency detection operation
03-1X=52: Frequency Detection
5
Please refer to
Table 4.4.9 Frequency detection operation
03-1X=53: Frequency Detection
6
Please refer to
Table 4.4.9 Frequency detection operation
03-13 Frequency detection Level
Set Range
0.0~599.0 Hz
03-14 Frequency detection width
Range
0.1~25.5 Hz
Frequency detection Level: set the multi-function output terminals R1A-R1C, R2A-R2C or PH1 (03-11, 03-12 or
03-28) to the desired detection level and bandwidth for use with multi-function output functions 2 to 5.
The time charts for the Frequency Agree Detection operation are shown in the following table 4.4.9.