4-362
4.7.8 Error Messages List
If Profibus DP communication option card cannot exchange data with Profibus network
communication or A510S, or communication card hardware fault occurs, inverter’s operator will
displays error messages and LED light of Profibus DP communication option card will flash so
Profibus DP communication option card cannot work normally. Error message list is as follows:
Message shown
in operator
LED light status in
Communication
card
Description Possible Cause
Communication
Error1
LED1 Flash
Communication
is interrupted
Profibus DP communication option card
does not receive the data from Profibus
network within the specified time.
Communication
Error 2
LED2 Flash
Dual-port RAM
fault
Dual-port RAM failure
Communication
Error 3
LED2 Flash
Dual-port RAM
checksum error
Checksum is not correct when dual-port
RAM exchanges data.
Communication
Error 4
LED2 Flash
Dual-port RAM
data error
Data is not correct when dual-port RAM
exchanges data.
4.7.9 GSD File
;/***********************************************************/
;/* Filename: Profibus-DP.GSD
;/* ModelName: TECO AC DRIVES A510 V2
;/* CreateDate: 2012.12.18
;/***********************************************************/
#Profibus_DP
GSD_Revision = 1
Vendor_Name = "TECO"
Model_Name = "A510 V2-P"
Revision = "Version0.0"
Ident_Number = 0xA510
Protocol_Ident = 0 ;Profibus-DP
Station_Type = 0 ;DP Slaver
FMS_supp = 0 ;Pure DP Device
Hardware_Release = "HW_V1.0"
Software_Release = "SW_V1.0"
;
9.6_supp = 1
19.2_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60