Group 01: V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
01-04
Middle Output
Frequency 2 of
Motor 1
0.0~599.0 0.0 Hz O O X X X X O
01-05
Middle Output
Voltage 2 of
Motor 1
200V: 0.0~255.0
0.0 V O O X X X X O
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0
01-06
Middle Output
Frequency 1 of
Motor 1
0.0~599.0 3.0 Hz O O X X X X O
01-07
Middle Output
Voltage 1 of
Motor 1
200V: 0.0~255.0
*
V O O X X X X O
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0
01-08
Minimum Output
Frequency of
Motor 1
0.0~599.0
VF:1.5
Hz O O O O O O O
VF+PG:
1.5
SLV:
0.6
SV:0.1
PMSV:
0.1
PMSLV
:9.0
SLV2:
1.0
01-09
Minimum Output
Voltage of Motor
1 (for 3~30HP)
200V: 0.0~255.0 7.5
V O O X X X X O
400V: 0.0~510.0
15.0
575V: 0.0~670.0
690V: 0.0~804.0
01-10
Torque
Compensation
Gain
0.0~2.0 0.5 - O O X X X X O *1
01-11
Selection of
Torque
Compensation
Mode
0: Torque
Compensation Mode
0
0 - O O X X X X X
1: Torque
Compensation Mode
1
01-12
Base Frequency
of Motor 1
5.0~599.0 60.0 Hz O O O O O O O
01-13
Base Output
Voltage of
Motor 1
200V: 0.0~255.0 220.0
V O O X X X X O
400V: 0.0~510.0 440.0
575V: 0.0~670.0 575.0
690V: 0.0~804.0 690.0
01-14
Input Voltage
Setting
200V: 155.0~255.0 220.0
V O O O O O O O 400V: 310.0~510.0 440.0
575V: 540.0~670.0 575.0