4-24
Group 01: V/F Control Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F
+PG
SLV SV
PM
SV
PM
SLV
SLV2
690V: 648.0~804.0 690.0
01-15
Torque
Compensation
Time
1~10000 200 ms O O X X X X O
01-16
Maximum Output
Frequency of
Motor 2
5.0~599.0 60.0 Hz O X X X X X X
01-17
Maximum Output
Voltage of Motor
2
200V: 0.1~255.0 220.0
V O X X X X X X
400V: 0.2~510.0 440.0
575V: 0.1~670.0 575.0
690V: 0.1~804.0 690.0
01-18
Middle Output
Frequency 2 of
Motor 2
0.0~599.0 0.0 Hz O X X X X X X
01-19
Middle Output
Voltage 2 of
Motor 2
200V: 0.0~255.0
0.0 V O X X X X X X
400V: 0.0~510.0
575V: 0.0~670.0
690V: 0.0~804.0
01-20
Middle Output
Frequency 1 of
Motor 2
0.0~599.0 3.0 Hz O X X X X X X
01-21
Middle Output
Voltage 1 of
Motor 2 (for
3~30HP)
200V: 0.0~255.0 14.0
V O X X X X X X
400V: 0.0~510.0
28.0
575V: 0.0~670.0
690V: 0.0~804.0
01-22
Minimum Output
Frequency of
Motor 2
0.0~599.0 1.5 Hz O X X X X X X
01-23
Minimum Output
Voltage of Motor
2 (for 3~30HP)
200V: 0.0~255.0 7.5
V O X X X X X X
400V: 0.0~510.0
15.0
575V: 0.0~670.0
690V: 0.0~804.0
01-24
Base Frequency
of Motor 2
5.0~599.0 60.0 Hz O X X X X X X
01-25
Base Output
Voltage of
Motor 2
200V: 0.0~255.0 220.0
V O X X X X X X
400V: 0.0~510.0 440.0
575V: 0.0~670.0 575.0
690V: 0.0~804.0 690.0
01-26
V/F Curve
Selection of
Motor 2
0~FF F - O X X X X X X *3
*: Refer to the attachment 1.