4-67
Group 16: LCD Function Parameters
Code Parameter Name Setting Range Default Unit
Control mode
Attribute
V/F
V/F+
PG
SLV SV
PM
SV
PMS
LV
SLV2
2: CFM
3: PSI
4: GPH
5: GPM
6: IN
7: FT
8: /s
9: /m
10: /h
11: °F
12: inW
13: HP
14: m/s
15: MPM
16: CMM
17: W
18: KW
19: m
20: °C
21: RPM
22: Bar
23: Pa
16-05
LCD Backlight 0~7
5 - O O O O O O O *1
16-06 Reserved
16-07
Copy Function
Selection
0: Do not copy
parameters
0 - O O O O O O O
1: Read inverter
parameters and save
to the operator.
2: Write the operator
parameters to inverter.
3: Compare parameters
of inverter and
operator.
16-08
Selection of
Allowing Reading
0: Do not allow to read
inverter parameters and
save to the operator.
0 - O O O O O O O
1: Allow to read inverter
parameters and save
to the operator.
16-09
Selection of
Operator
Removed (LCD)
0: Keep operating when
LCD operator is
removed.
0 - O O O O O O O *1
1: Display fault when LCD
operator is removed

Table of Contents