4-116
Type Specification 01-00 setting V/F curve
*1
High speed motor
1200Hz
F
(Set 00-31 to 1 )
(Hz)
200
1200
0
200
(V)
7.8
400
57.5
800
*1. Values shown are for 200V class inverters; double values for 400V class inverters.