4-312
Attachment 1: Parameters’ default value and upper limit value are adjusted by different capacities of
inverter.
Models Frame
Max. frequency
(Hz) in SLV
when carrier
frequency <= 8K
Max. frequency
(
Hz
)
in SLV when
carrier frequenc
y
> 8K
Display
parameter
12-41 (Inverter
temperature)
The initial value of
parameter 18-00 in
SLV/ SV (Slip
compensation at
low speed)
2001
1 150 150 Yes 1.00
2002
2003
2 150 150 Yes 1.00 2005
2008
2010 3 150 150 Yes 1.00
2015
4 110 110 Yes 1.00 2020
2025
2030
5 100 80 Yes 0.70
2040
2050
6 100 80 No 0.70
2060
2075
7 100 95 No 0.50
2100
2125
8 100 80 No 0.50
2150
4001
1 150 150 Yes 1.00 4002
4003
4005
2 150 150 Yes 1.00
4008
4010
3 150 150 Yes 1.00
4015
4020
4
110 110
Yes 1.00 4025 100 100
4030 100 100
4040
5 100 80 Yes 0.70
4050
4060
4075
4100
6 100 80 No 0.70
4125
4150
7 100 80 No 0.50
4175
4215
4270
8 100 80 No 0.50 4300
4375
4425

Table of Contents