Appendix 1 Relationship between the Time Axis
Setting, Sample Rate and Record Length
T/div
500ns
1 µs
2 µs
5 µs
10 µs
20 µs
50 µs
100 µs
200 µs
500 µs
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
3 s
4 s
5 s
6 s
8 s
10 s
20 s
30 s
1 min
2 min
3 min
4 min
5 min
6 min
7 min
8 min
9 min
10 min
12 min
15 min
30 min
1 h
2 h
3 h
4 h
5 h
6 h
7 h
8 h
9 h
10 h
12 h
1 day
2 day
3 day
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
500
200
100
50
20
20
20
10
10
10
5
50
100
200
500
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
1 k
600
800
1 k
600
800
1 k
1 k
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
500
200
100
50
50
50
20
20
20
10
5
50
100
200
500
1 k
2 k
2.5 k
2 k
2 k
2.5 k
2 k
2 k
2.5 k
2 k
2 k
2.5 k
2 k
2 k
2.5 k
2 k
2 k
1.5 k
2 k
2.5 k
1.2 k
1.6 k
2 k
2 k
1.5 k
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
500
200
100
100
100
50
50
50
20
10
5
50
100
200
500
1 k
2 k
5 k
5 k
4 k
5 k
5 k
4 k
5 k
5 k
4 k
5 k
5 k
4 k
5 k
5 k
4 k
3 k
4 k
5 k
3 k
4 k
5 k
4 k
3 k
3 k
Record Length
1 kW 2.5 kW 5 kW
Sample
Rate
(S/s)
Sample
Rate
(S/s)
Display
Record
Length
(Word)
Display
Record
Length
(Word)
Display
Record
Length
(Word)
Sample
Rate
(S/s)
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
500
200
200
200
100
100
100
50
20
10
5
5
50
100
200
500
1 k
2 k
5 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
10 k
6 k
8 k
10 k
6 k
8 k
10 k
10 k
6 k
6 k
6 k
9 k
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
10 M
5 M
2 M
1 M
500 k
200 k
100 k
50 k
20 k
10 k
5 k
2 k
1 k
500
500
500
200
200
200
100
50
20
20
10
10
5
5
5
50
100
200
500
1 k
2 k
5 k
10 k
20 k
25 k
20 k
20 k
25 k
20 k
20 k
25 k
20 k
20 k
25 k
20 k
20 k
15 k
20 k
25 k
12 k
16 k
20 k
20 k
15 k
12 k
24 k
18 k
24 k
15 k
18 k
21 k
10 kW 25 kW
Sample
Rate
(S/s)
Sample
Rate
(S/s)
Display
Record
Length
(Word)
Display
Record
Length
(Word)
For the settings inside the thick frame, the waveform is displayed in roll mode when the trigger mode is set
to auto or auto-level.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL750 and is the answer not in the manual?

YOKOGAWA DL750 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL750
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals