2. Safety Marathon Express
Mechanical Hazards Part Number: 605914 Rev. B
ThefollowingaregeneralrecommendationsforLOCKOUTorTAGOUTforsystemsmanufactured
byBrooksAutomation.
l
UseLOCKOUTforallpowersources(highvoltageelectrical,air,nitrogen,water,etc.)
l
UseTAGOUTforlowvoltage(below30volts)electricalcircuitrepair
l
UseTAGOUTformaintenance,cleaning,orlubricatingmovingparts
l
UseTAGOUTforclearingjammedpartsormechanisms
Mechanical Hazards
TheBrooksAutomationMarathonExpressisacomplexelectromechanicaldevice.Onlypersons
withthepropertrainingshouldattempttoserviceoroperatetheanypartofthematerialtransfer
tool.
AllfacilitiestotheMarathonExpressmustbedisconnectedasoutlinedinthefacility’s
lockout/tagoutproceduresbeforeservicing,orinjurymayresultfromtheautomaticoperationofthe
equipment.Ifnosuchproceduresexist,followtheguidelinesprovidedin"LaserHazards"onpage
46.Theproperprecautionsforoperatingandservicingremotelycontrolledelectromechanical
equipmentmustbeobserved.Theseprecautionsincludewearingahardhat,safetyglasses,safety
shoes,andanyotherprecautionsspecifiedwithinthefacilitywheretheMarathonExpressisbeing
used.
Automatic Movement / Crush hazard
WheneverpowerisappliedtotheMarathonExpress,thepossibilityexistsofautomatic
movementthatcancauseseriousinjuryordeath.Thesecomponentsinclude:
l
Robot
l
Aligner
l
CoolModulePoppet
l
LoadLockModule(s)(AutoDoor,Arm,Platform)
l
AtmosphericDoors
l
VacuumSlotValves
l
IsolationValves
l
Pumps
Movingmechanismsdonothaveobstructionsensorsandcancauseseriouspersonal
injuryordeath.
DonotoperatetheMarathonExpresswithouttheprotectivecoversinplaceandall
safetyinterlocksenabled.
Donotoperatetherobotwithouttheprotectivecoversinplace.
DonotoperatetheVacuumSlotValvesorAtmosphericDoorswhenthechamberlidis
open.