6
PREPARATORY PROCEDURES AND SETTING
6.4 Part Names and Functions
6.4.2 Part names and functions of the Q06CCPU-V(-B)
6 - 33
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
(1) Indicator LED specifications
(a) In normal operation mode (when the MODE LED is on (green))
The operation mode is changed by switches. ( (2), (3) in this section)
* 1 All of the LEDs turn off while the module is reset.
* 2 When a system watchdog timer error occurs, the RUN and MODE LEDs turn off and the ERR. LED
flashes.
Figure 6.28 Indicator LEDs
Table 6.12 Indicator LEDs and their states in normal operation mode
Indicator
LED
*1
LED status Description
RUN
On
The C Controller module is in the RUN status.
(Output (Y) from a user program and writing to the buffer memory are enabled.)
Off
The C Controller module is in the STOP/PAUSE status.
(Output (Y) from a user program and writing to the buffer memory are disabled.)
Flashing The script file "STARTUP.CMD" is in execution.
MODE
On Normal operation mode (VxWorks is running.)
Off A hardware failure occurred or the C Controller module is in reset process.
Flashing
Shutdown is completed. ( Page 6-58, Section 6.7.5 (1))
ERR.
On A continuation error occurred.
Off Normal
Flashing
A stop error occurred.
*2
USER
On
This LED can be controlled with the QBF_ControlLED function in user programs.
( C Controller Module User's Manual (Utility Operation, Programming))
Off
Flashing
CF CARD
On
A CompactFlash card is mounted. (
Page 6-64, Section 6.8.2)
Off
A CompactFlash card is not installed or unmounted. (
Page 6-64, Section 6.8.2)
Flashing
A CompactFlash card is unmounted by the RESET/SELECT switch. (
Page 6-67,
Section 6.8.3)
STS Off Always off
100M
On Connected at 100Mbps.
Off Connected at 10Mbps.
SD/RD
On Data are being sent or received through CH1 (10BASE-T/100BASE-TX interface).
Off No data communication
CH2 SD/RD
On Data are being sent or received through CH2 (RS-232 interface).
Off No data communication
100
M
SD/
RD
100BASE-TX
CH1 10BASE-T/
MODE
ERR.
USER
RUN
CF CARD
CH2 SD/RD
Q06CCPU-V
Q06CCPU-V
MODE
ERR.
USER
RUN
STS
CH2 SD/RD
Q06CCPU-V-B
Q06CCPU-V-B