Chapter 20: LPC11U3x/2x/1x Flash programming firmware
20.13.2 Set Baud Rate <Baud Rate> <stop bit>
20.13.3 Echo <setting>
20.13.4 Write to RAM <start address> <number of bytes>
The host should send the data only after receiving the CMD_SUCCESS return code. The
host should send the check-sum after transmitting 20 UU-encoded lines. The checksum is
generated by adding raw data (before UU-encoding) bytes and is reset after transmitting
20 UU-encoded lines. The length of any UU-encoded line should not exceed
61 characters (bytes) i.e. it can hold 45 data bytes. When the data fits in less than
20 UU-encoded lines then the check-sum should be of the actual number of bytes sent.
The ISP command handler compares it with the check-sum of the received bytes. If the
check-sum matches, the ISP command handler responds with "OK<CR><LF>" to
continue further transmission. If the check-sum does not match, the ISP command
handler responds with "RESEND<CR><LF>". In response the host should retransmit the
bytes.
Table 367. ISP Set Baud Rate command
Command B
Input Baud Rate: 9600 | 19200 | 38400 | 57600 | 115200
Stop bit: 1 | 2
Return Code CMD_SUCCESS |
INVALID_BAUD_RATE |
INVALID_STOP_BIT |
PARAM_ERROR
Description This command is used to change the baud rate. The new baud rate is effective
after the command handler sends the CMD_SUCCESS return code.
Example "B 57600 1<CR><LF>" sets the serial port to baud rate 57600 bps and 1 stop bit.
Table 368. ISP Echo command
Command A
Input Setting: ON = 1 | OFF = 0
Return Code CMD_SUCCESS |
PARAM_ERROR
Description The default setting for echo command is ON. When ON the ISP command handler
sends the received serial data back to the host.
Example "A 0<CR><LF>" turns echo off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NXP Semiconductors LPC11U3x and is the answer not in the manual?

NXP Semiconductors LPC11U3x Specifications

General IconGeneral
BrandNXP Semiconductors
ModelLPC11U3x
CategoryMicrocontrollers
LanguageEnglish

Related product manuals