OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-85
5.5.8 System Error 1410: FPGA(ABC) Load Error
<Description>
Failed to write config from the flash ROM on the PCB-ASSY-IPB5-100 to the ASIC on the
PCB-ASSY-ACT3.
<Faulty part>
(1) PCB-ASSY-ACT3
(2) PCB-ASSY-IPB5-100
<Action>
Restart the printer.
If the error persists, check the Items to be Checked on the table below, and perform the actions
starting from the top until the problem is solved.
Upgrade the firmware to the latest version.
PCB-ASSY-IPB5-100 and
PCB-ASSY-ACT3 cables
Check that the cable condition is proper as follows.
- The connectors are connected securely.
- The cable is not disconnected.
- The cable is not pinched by other parts.
- The cable jacket is not damaged.
Replace the PCB-ASSY-ACT3.
Replace the PCB-ASSY-IPB5-100.