EasyManua.ls Logo

Oki IP-6620 - 5.6 If No Error Message Appears; 5.6.1 Nothing is displayed

Oki IP-6620
572 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OKI Data Infotech Corporation CONFIDENTIAL
Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-155
5.6 If No Error Message Appears
5.6.1 Nothing is displayed
<Description>
Normally the message Booting up… appears when initializing the system program. An error has
occurred if this message is not displayed.
<Faulty part>
(1) PANEL, MW (operation panel)
(2) PCB-ASSY-IPB5-100
(3) Panel cable: CABLE(PANEL)-ASSY(MW)
(4) CABLE(ACT-IPB-IF)-ASSY(MW)
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
Action
1
Firmware
Upgrade the firmware to the latest version.
2
CABLE(ACT-IPB-IF)-ASSY(MW)
Check the harness condition and that the connectors are
connected securely.
3
Panel cable’s harness condition
Check that the harness condition is proper as follows.
- The connectors are connected securely.
- The cable is not disconnected.
- The harness is not pinched by other parts.
- The cable jacket is not damaged.
If the harness is damaged, replace it.
4
PANEL, MW (operation panel)
Replace the PANEL, MW.
5
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.