5.5.28 System Error 2210: USB DMA Time-out
<Description>
USB data transmission DMA was not completed from the USB controller to the band memory.
<Faulty part>
PCB-ASSY-IPB5-100
<Action>
Restart the printer.
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
Action
1
Firmware
Upgrade the firmware to the latest version.
2
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.