5.5.49 System Error 2c0X: Ionizer Voltage Error
<Description>
An abnormal voltage has been detected during the ionizer feedback voltage check.
X
Ionizer error
0
A value exceeding the voltage upper limit of the (+) module has
been detected.
1
A value exceeding the voltage lower limit of the (+) module has
been detected.
2
A value exceeding the voltage upper limit of the (-) module has
been detected.
3
A value exceeding the voltage lower limit of the (-) module has
been detected.
<Faulty part>
(1) IONIZER UNIT, MW
(2) PCB-ASSY-HCB1M
(3) CABLE(ADJ-AD)-ASSY
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
No
Items to be Checked
Action
1
Harness condition
Check that the harness condition is proper as follows.
- The connectors are connected securely.
- The cable is not disconnected.
- The harness is not pinched by other parts.
- The cable jacket is not damaged.
If the harness is damaged, replace it.
2
Ionizer
Replace the ionizer.
3
PCB-ASSY-HCB1M
Replace the PCB-ASSY-HCB1M.