Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-137
5.5.49 System Error 2c0X: Ionizer Voltage Error
<Description>
An abnormal voltage has been detected during the ionizer feedback voltage check.
A value exceeding the voltage upper limit of the (+) module has
been detected.
A value exceeding the voltage lower limit of the (+) module has
been detected.
A value exceeding the voltage upper limit of the (-) module has
been detected.
A value exceeding the voltage lower limit of the (-) module has
been detected.
<Faulty part>
(1) IONIZER UNIT, MW
(2) PCB-ASSY-HCB1M
(3) CABLE(ADJ-AD)-ASSY
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top
until the problem is solved.
Check that the harness condition is proper as follows.
- The connectors are connected securely.
- The cable is not disconnected.
- The harness is not pinched by other parts.
- The cable jacket is not damaged.
If the harness is damaged, replace it.
Replace the PCB-ASSY-HCB1M.