Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-43
5.3.7 Others
<Description>
The front cover is open.
<Action>
Close the front cover securely.
If the error persists, check the Items to be Checked on the table below, and perform the actions
starting from the top until the problem is solved.
No
Items to be Checked
Action
1
Connection of the connector on the
front cover switch harness
Check that the harness connector is securely connected to
the board’s connector.
2
Condition of the front cover switch
harness
Check that the harness condition is proper as follows.
- The cable is not disconnected.
- The harness is not pinched by other parts.
- The cable jacket is not damaged.
If a problem is found, replace the harness.
3
Front cover switch
Replace the switch.
4
PCB-ASSY-ACT3
Replace the PCB-ASSY-ACT3.
When the temperature is too high before the printing starts
When the temperature is too high during printing
When the temperature is too low
<Description>
Ambient temperature is not within the printer’s operating temperature range.
DECREASE ROOM TEMP
AND WAIT FOR A WHILE
DECREASE ROOM TEMP
QUALITY ND UNI
ROOM TEMP TOO HIGH
PRINT? OK/CANCEL â—Ž
CLOSE COVER