<Removal>
1. Move the carriage to the maintenance
area.
2. Remove the CAPPING-UNIT-MW.
3. Remove the screw securing the
LEVER(CAP)-HV-ASSY, remove the
SCREW(CAM-LOCK-HV), disconnect
the connector of the connected cable,
and then remove the
LEVER(CAP)-HV-ASSY (with the
MICRO SWITCH 4 inside).
Note
When installing the LEVER(CAP)-HV-ASSY
and the SCREW(CAM-LOCK-HV), place the
cap at the middle height. Avoid the highest
and the lowest position for the cap.
LEVER(CAP)-HV-ASSY
SCREW(CAM-LOCK-HV)