Chapter 5 Troubleshooting (Engine Section and USB Controller Section)
5-98
Case 4
The problem below occurred:
X=9 (PCB-ASSY-IPB5-100 P38VCRG)
Note:
The power supply system related to this error number is generated from the PSU 38V, and the
power is supplied to the PCB-ASSY-IPB5-100 after passing through the interlock relay. So
check the Items to be Checked on the table below, and perform the actions starting from the
top until the problem is solved.
No
Items to be Checked
Action
1
Check that the printer detects
the interlock switch position
(ON/OFF)
Open and close the front cover, and check that the printer
detects the interlock switch position.
If the Printer does not react to the interlock switch position,
check that the PCB-ASSY-ACT3s connector CN2 is
connected.
If the error persists, check the interlock switchs connector is
connected.
If the error still persists, replace the interlock switch.
2
Cable between the ACT3 and
IPB5
Reconnect the CABLE(ACT-IPB-IF)-ASSY(MW) to the
ACT3 and the IPB5.
3
PCB-ASSY-ACT3
Replace the PCB-ASSY-ACT3.
4
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.
5
Power supply unit (38V)
Replace the power supply unit (38V).
Case 5
The problem below occurred:
X1 (PCB-ASSY-ACT3 P24V)
Note:
The power supply system related to this error number is generated from the PSU 24V, and the
power does not pass through the interlock relay. So check the Items to be Checked on the
table below, and perform the actions starting from the top until the problem is solved.
No
Items to be Checked
Action
1
Power supply unit (24V)
harness
(1) Reconnect the CABLE(PSU-ACT-IF)-ASSY(MW) to
the ACT3 and the power supply.
(2) Reconnect the CABLE(PSU-ACT)-ASSY(MW) to the
ACT3 and the power supply.
2
Cable between the ACT3 and
IPB5
Reconnect the CABLE(ACT-IPB-IF)-ASSY(MW) to the
ACT3 and the IPB5.
3
PCB-ASSY-ACT3
Replace the PCB-ASSY-ACT3.
4
PCB-ASSY-IPB5-100
Replace the PCB-ASSY-IPB5-100.
5
Power supply unit (24V)
Replace the power supply unit (24V).