6-100
4. Apply sheet mount cleaning liquid onto
the entire inside surface of the outside
edge of the joints (CAP Sa). (There is no
problem if the liquid also adheres to the
inside edge.)
5. Adjust the springs so that they are
placed perpendicular to the cap, and
rotate them clockwise two turns or more
to insert them. Check that the surfaces of
all the springs are at the same height.
6. Place the cap so that the side with the
SHEET(CAP) hole comes to the solenoid
side.
Make sure that the springs enter the
three tubes on the FRAME(UD-HV), and
then set the cap carefully.
SHEET(CAP) hole
Solenoid side
FRAME(UD-HV)
Sheet mount
cleaning liquid
Joint (CAP Sa)
Perpendicular