Chapter 3 Maintenance Mode Functions and Operations
3-39
(i) MEDIA HEATERS
YYYYYYYY: Setting after change
Parameter
Description
Remark
OFF
Stopped
55-55-55
Each heater operates until it reaches the limit
temperature below.
- Afterheater: 55°C
- Printheater: 55°C
- Preheater: 55°C
45-40-45
Each heater operates until it reaches the following
temperature required to adjust the platen flatness.
- Afterheater: 45°C
- Printheater: 40°C
- Preheater: 45°C
(ii) PRINT HEAD HEATERS
YYYYYYYY: Setting after change
Parameter
Description
Remark
OFF
Stopped
30°C
Heat each print head until they reach 30°C.
* The temperature is set uniformly so that this menu is used to check that the print head
heaters are operating.
>>>>PRINT HEAD HEATERS
YYYY
>>>>MEDIA HEATERS
YYYYYYYY