10. Service Mode Field Service Ver. 1.0 Jun. 2008
168
Adjustment / Setting
10.4.7 Toner Supply
10.4.8 Monochrome Density Adjustment
10.4.9 Dev. Bias Choice
Functions To adjust the set T/C level by replenishing an auxiliary supply of toner when a low ID
occurs due to a lowered T/C after large numbers of prints have been made of origi-
nals having a high image density.
Use When there is a drop in T/C.
Setting/
Procedure
1. Call the Service Mode to the screen.
2. Touch these keys in this order: [Imaging Process Adjustment] o [Toner Supply].
3. Select the color, for which supply of toner is to be replenished.
4. Pressing the Start key will let the machine detect the current toner density and; if the
density is lower than a reference value, a toner replenishing sequence and then a
developer agitation sequence are run.
5. These sequences are repeated up to a maximum of four times until the toner density
reaches the reference value. If the toner density is found to be higher than the refer-
ence value, only a developer agitation sequence is carried out.
Functions To fine-adjust the density of the printed image for a black print.
Use To vary the density of the printed image of a black print.
Adjustment
Range
The default setting is 0.
-2 to +2 (step: 1)
Adjustment
Instructions
If the black is light, touch [+].
If the black is dark, touch [-].
Setting/
Procedure
1. Call the Service Mode to the screen.
2. Touch these keys in this order: [Imaging Process Adjustment] o [Monochrome Den-
sity Adjustment].
3. Change the setting value using the [+] / [-] keys.
Functions To change the setting of the developing bias voltage.
When this function is turned ON, it decreases the developing bias voltage, thereby
preventing voltage leak from occurring.
Use Use when patches of white occur in the image in an ambience of low atmospheric
pressure, such as in high altitudes.
If ON is set, the screen doesn’t display [Service Mode] o [Imaging Process Adjust-
ment] o [Gradation Adjust] and the Gradation Adjust is not allowed.
Setting/
Procedure
The default setting is OFF.
ON “OFF”
d-Color MF201
Service Manual Y109660-1
d-Color MF201

Table of Contents

Other manuals for Olivetti d-Color MF201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olivetti d-Color MF201 and is the answer not in the manual?

Olivetti d-Color MF201 Specifications

General IconGeneral
BrandOlivetti
Modeld-Color MF201
CategoryAll in One Printer
LanguageEnglish

Related product manuals