Field Service Ver. 1.0 Jun. 2008 10. Service Mode
251
Adjustment / Setting
10.5.11 Consumable Life Reminder
10.5.12 Unit Change
10.5.13 Option Settings
Mode Default value
884
Bit 7654 3210
HEX: 01
State 0000 0001
Bit Setting item
Setting value
Description
01
0 Fan control for the low-temperature warm-up
*: In order to make this setting valid, main
power switch needs to be turned off and on
twice.
Valid
Invalid
Sets the valid/invalid of
the fan control function
which further prevents the
waviness of the paper
when printing immediately
after the warm-up in low
temperature.
Functions • To select whether or not to give the display of PM parts lifetime
PM parts lifetime display: An entire screen warning is given when the service life
of a specific unit has been reached, prompting the
user to replace the part.
• Applicable units:
Transfer belt unit, fusing unit, imaging unit (C, M, Y, K)
Use • Use to select not to give the display of PM parts lifetime.
Setting/
Procedure
• The default setting is “Yes.”
“Yes” No
Functions • To select who is to replace a unit.
• When the unit life arrives, the warning display is intended for the specific person who
is going to replace the unit.
When “User” is selected : Printing is inhibited.
When “Service” is selected: Life warning.
Use • Upon setup
Setting/
Procedure
<Unit Change>
• The following are the default settings:
US, Japan, Others 2 Europe, Others1,3,4
Toner Cartridge : “User” Service “User” Service
Imaging Unit : User “Service” “User” Service
Waste Toner Box : User “Service” “User” Service
Functions • To set the status for the optional stamp unit SP-503.
Use • To be used for setting up the stamp unit SP-503.
Setting/
Procedure
• The default setting is “No.”
Ye s “ N o ”