10. Service Mode Field Service Ver. 1.0 Jun. 2008
196
Adjustment / Setting
Mode Default value
330
Bit 7654 3210
HEX: 01
State 0000 0001
Bit Setting item
Setting value
Description
01
7-0 Wait time from when cover is closed until
main scan direction size detection starts
00000000 0
00000001 200 msec
00000010 400 msec
00000011 800 msec
others Not available
Mode Default value
331
Bit 7654 3210
HEX: 60
State 0110 0000
Bit Setting item
Setting value
Description
01
7-0 To prevent mis-detection:
Minimum value for scanning when closing
cover
00000000 0
00000001 1 gradation
:
01100000 96 gradations
:
11111111 255 gradations
Mode Default value
332
Bit 7654 3210
HEX: 80
State 1000 0000
Bit Setting item
Setting value
Description
01
7-0 To prevent mis-detection:
Maximum value for scanning when opening
cover
00000000 0
00000001 1 gradation
:
10000000 128 gradations
:
11111111 255 gradations
d-Color MF201