Chapter 5  Troubleshooting
Before Contacting Quantum Support
SuperLoader User’s Guide 131
The front panel and light 
indicators do not turn 
on.
• Verify that the SuperLoader is plugged in.
• Verify that the power switch on the back is 
turned on.
• Verify that the DCA is locked into the 
SuperLoader chassis with the four screws 
supplied.
• Contact your Service Provider or Quantum 
Support.
The front panel does not 
display information, but 
light indicators above 
the front panel are 
turned on.
• Connect to the SuperLoader, using On-
board Remote Management with an 
Ethernet connection and issue a 
Reset from 
the Diagnostic page.
• Verify that the DCA is locked into the 
SuperLoader chassis with the four screws 
supplied.
• On the front panel, press and hold the 
power switch for 15 seconds, then turn the 
rear power switch off. Wait 60 seconds and 
turn the rear power switch back on.
• Contact your Service Provider or Quantum 
Support.
Problem Probable Cause Suggested Action