EasyManuals Logo

Quantum Superloader 3 User Manual

Quantum Superloader 3
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
Chapter 5 Troubleshooting
Before Contacting Quantum Support
SuperLoader User’s Guide 133
The SuperLoader does
not communicate with
the Host system via the
Ethernet.
Verify that the Ethernet cable is connected
to the correct hub.
Verify the Ethernet configuration settings
via the front panel. If the DHCP server is
available, Ethernet status should indicate
DHCP, otherwise you must set a unique IP
address and mask.
Power off the SuperLoader by turning off
the system from the front panel and
turning it back on.
Contact your Service Provider or Quantum
Support.
The application software
reports a failure locating
a piece of media or fails
to move a piece of media
as requested.
Use the On-board Remote Management
page and verify that the media is in the
expected location internal to the
SuperLoader.
Using the On-board Remote Management
diagnostic tool, execute the
Health Check
command.
•Issue a
System Reset either by using the
On-board Remote Management Diagnostic
System Reset or by turning the power off
from the front panel.
Contact your Service Provider or Quantum
Support.
Problem Probable Cause Suggested Action

Table of Contents

Other manuals for Quantum Superloader 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Superloader 3 and is the answer not in the manual?

Quantum Superloader 3 Specifications

General IconGeneral
Product TypeTape Autoloader
Number of Tape Drives Installed1
Number of Cartridge Slots8
Tape TechnologyLTO Ultrium
Data Compression Ratio2:1
Native Capacity12 TB
Compressed Capacity24 TB
InterfacesSAS
Humidity20% to 80% non-condensing
Operating Temperature10°C to 35°C
Supported MediaLTO-5, LTO-4